E2S GNExB1X05 Xenon Strobe Beacon

  • The GNExB1X05 is an IECEx & ATEX approved explosion proof 5 Joule Xenon beacon. The robust IP66 corrosion proof sturdy GRP enclosure and extended temperature range ensures the GNExB1X05 is suitable for all Zone 1,2,21,22 hazardous location signalling applications.
  • The GNExB1X05 beacon produces over 117cd effective - a high output Xenon strobe flash required for safety signalling. The field replaceable colour filter enhances the strobe and is constructed from UV stable PC. The GRP enclosure features a threaded flame path, dual cable entries and a large termination area - all of which significantly reduce installation time.
  • Key Features
  • - Robust, corrosion proof GRP (glass reinforced polyester) enclosure
  • - Ingress protection IP66
  • - Automatic synchronisation on multi-beacon systems
  • - DC voltage versions feature a choice of three flash rates
  • - DC voltage units feature remote initiation of flash rate
  • - User replaceable Xenon tube mechanically secured against shock & vibration
  • - Glass lens & Stainless Steel guard
  • - UV stable PC field replaceable lens colour filter
  • - Stainless steel fixings
  • - Dual cable entries
  • - Duplicate cable terminations (in & out for daisy-chain installations)
ce belgeli

Price : On Request
 
 
Technical Specifications
Ordering Code :
GNEXB2LD2DC024AB1
Energy : 5 Joules (5Ws)
Flash Rate : DC voltages: 1Hz (60fpm), 1.5Hz (90fpm) & double flash AC voltages: 1Hz (60fpm)
Alarm Stage : DC units - 2 , Double strike pattern can be remotely switched
Peak Candela : 500,000 cd - calculated from energy (J)
Source :
Array of 4 x High Power Cree® LED's
Modes :
1Hz flash (60 fpm)
1.5Hz flash (90 fpm)
2Hz flash (120 fpm)
Double strike flash
Triple strike flash
High Power Steady
Low Power Steady
Effective Intensity (cd) : 250 cd - calculated from energy (J)
Peak Candela (cd):

45,449 cd - measured ref to I.E.S

Effective Intensity (cd) : 117.93 cd - measured ref to I.E.S
Lens Color :
Amber, Blue, Clear, Green, Magenta, Red & Yellow
Supply Voltage(DC) : 12Vdc; 24vdc; 48Vdc
Supply Voltage(AC) :
115V AC ; 220V AC
Ingress Protection Rate :
IP66
Current Consumption : 822mA @20-28VDC , 342mA @42-54VDC , 328mA @110-125VAC , 168mA @220-240VAC
Enclosure Material : UV stable GRP (glass reinforced polyester)
Color : Natural Red
Cable Entries : 2 x M20 ISO (1 stopping plug inc.) Adaptors to M25, 1/2" & 3/4" NPT can be specified
Terminal : 0.5 to 2.5mm²
Enclosure Volume : <2 litres
Line Monitor : Blocking diode included , EOL Min. 500 Ohm 2w , or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted
Tube Life : Emissions are reduced to 70% after 5 million flashes
Operating Temperature : -50° to +70°C (-58°F to +158°F)
Relative Humidity : 95% - Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight : 1.5kg/3.3lbs
Coding :
  • II 2G Ex db IIC Gb T6 Ta -50°C to +40°C
  • II 2G Ex db IIC Gb T5 Ta -50°C to +55°C
  • II 2G Ex db IIC Gb T4 Ta -50°C to +70°C
  • II 2D Ex tb IIIC Db T110°C Ta -50°C to +70°
Approval :
  • IECEx UL 15.0003X 
    IEC 60079-0 : 2011 
    IEC 60079-1 : 2014 
    IEC 60079-31 : 2013

  • ATEX DEMKO 15ATEX1448X 
    EN 60079-0 : 2012 
    EN 60079-1 : 2014 
    EN 60079-31 : 2014

  • TR-CU Ex EAC certificate: RU C-GB.AA71.B.00109

 
Dimensions

 
 
Other Products We Recommend

CP-550DB-Alarm Sounder
Price:On-Request
CP-750CDB-Sounder Beacon
Price:On-Request
Sigma -Protective Covers
Price:On-Request
 

  • Design and specifications are subject to change without prior notice.
 
Bookmark and Share
FURKAN ENGINEERING 2019
www.furkanmuhendislik.com.tr | info@furkanmuhendislik.com.tr